What is bpdu guard and how to configure bpdu guard in. If the interface receives incompatible bpdus, it is disabled. Two important bridge protocol data unit bpdu frames which switches exchange are configuration bridge protocol data units bpdus and topology. After configuring this feature at the vsphere host level, the bpdu frames from any virtual machine will be dropped by the virtual switch. Switches that receive this bpdu on the root port filter the database and generate their own configuration bpdus on designated ports. Catalyst 3750x and 3560x switch software configuration. Bpdu packets contain information on ports, addresses, priorities and costs and ensure that the data ends up where it was intended to go. With bpdu filter any incoming bpdus are simply dropped, but the switch port is not disabled. After all, at least one bit is needed to say this is a tcn bpdu, not a configuration bpdu. It seems unlikely to be a configuration issue if it worked for a year until now.
This factor of time is not an issue for many people, but it can cause problems for some. Catalyst 3560 switch software configuration guide, release. Configuring bpdu protection on interfaces to prevent. Recently i red document port acls pacls and vlan acls vacls which is the part of catalyst 6500 software configuration guide and noticed there following. See configuring bpdu protection on spanning tree interfaces for additional information. Remove the interface bpdu guard configuration from sw1 interface fa010 and configure system default portfast and bpduguard, verify the configuration. The time spanning tree protocol stp takes to transition ports over to the forwarding state can cause problems.
Configure bridge protocol data unit bpdu protection on a specified interface or on all interfaces. Bpdu protection for spanningtree protocols techlibrary. Hello tomas, from the config guide for your switch and release. Bpdu guard feature is used to protect the layer 2 spanning tree protocol stp topology from bpdu related attacks. Spanning tree portfast bpdu guard enhancement cisco. View and download cisco catalyst 2360 software configuration manual online.
In my topology above we have a perfectly working spanning tree topology. Issue this command in order to enable stp portfast bpdu guard on the switch. An mstp switch also can detect that a port is at the boundary of a region when it receives a legacy bpdu, an mstp bpdu version 3 associated with a different region, or an rstp bpdu version 2. Cisco nexus 5000 series nxos software configuration guide. All spanningtree protocols use a special type of frame called a bpdu to communicate. The devices, being in an rstp, support a loopfree network through the exchange of bpdus. Second, when redundant loops are planned on a network, stp deals with remediation of network.
Nov 19, 2012 to prevent such denail of service attack scenarios, bpdu filter feature is supported as part of the vsphere 5. First, it prevents problems caused by loops on a network. Cisco enterprise network function virtualization infrastructure software configuration guide, release 3. At the interface level, you enable bpdu guard on any stp port by using the spanningtree bpduguard enable interface configuration command. If this happens, ftos places the port in errordisable state. Bpdus are data messages that are exchanged across the switches within an extended lan that uses a spanning tree protocol topology. If you have not configured a port as an edge port, you can still configure bpdu protection on the interface by using the bpdublock command under the set ethernetswitchingoptions hierarchy.
If the disabletimeout statement is included in the bpdu configuration, the interface is automatically reenabled after the timer expires. Me 3800x and me 3600x switches software configuration. Configuring spanning tree portfast, bpdu guard, bpdu. Aug 08, 2016 it does say about bpdu guard not supported on wic4esw card slots which is fine but doesnt talk about the normal fastethernet interface on the 1751 router if that supports bpdu or not, and if yes, then i need to disable it. To save my self configuring portfast on every access port with bpdu guard and bpdu filter, i can simply enter these three global configuration commands.
Cisco and force10 stp spanning tree interoperability. If you have not configured a port as an edge port, you can still configure bpdu protection on the interface by using the bpdu block command under the set ethernetswitchingoptions hierarchy. The tcn bpdu is much simpler than the configuration bpdu illustrated in figure 615 and consists of only three fields. However, the switch does not automatically revert to the rstp mode if it no longer receives ieee 802.
Configuring switchport spanning tree bpdu guard free. Catalyst 3560 switch software configuration guide, release 12. Cisco switches use pvst by default which is a cisco proprietary protocol that runs one spanning tree instance per vlan. Consolidated platform configuration guide, cisco ios release. Spanning tree can fall victim to attacks,such as an attacker sending multiple bpdu messages. Catalyst 4500 series, catalyst 2948g, catalyst 2948ggetx, and catalyst 2980g switches software configuration guiderelease 8. Solved bpdu errors on every port, catalyst 2960s cisco. Protecting against bridging loop the traditional stp offers the portfast feature, in which switch ports are allowed to immediately enter the forwarding state as soon as the link comes up. Apr 15, 2016 if this switch receives a legacy ieee 802.
Receiving a bpdu on a port fastenabled port means an invalid configuration, such as the connection of an unauthorized device, and the bpdu guard feature puts the port in the errordisabled state. Srx series devices provide layer 2 loop prevention through rapid spanning tree protocol rstp and multiple spanning tree protocol mstp. Configuring bpdu protection on stp interfaces to prevent stp miscalculations on ex series switches 1 this example shows you how to configure interface ge005 and interface ge006 as edge ports and to configure bpdu protection. Tcn bpdus are identical to the first three fields of a configuration bpdu with the exception of a single bit in the type field. Cisco ons 15454 and cisco ons 15454 sdh ethernet card. Cisco introduced several enhancements to the standard stp operation that were later incorporated in rapid spanning tree protocol rstp defined as ieee 802. Configuring bpdu protection on spanning tree interfaces note. The issue im having seems like it has a simple solution that im just overlooking. The spanning tree protocol stp portfast is enabled only on access ports to speed up the transition of access port to. It does say about bpdu guard not supported on wic4esw card slots which is fine but doesnt talk about the normal fastethernet interface on the 1751 router if that supports bpdu or not, and if yes, then i need to disable it. In this course, russell long prepares you for the switching portion of the interconnecting cisco networking devices part 2 icnd2 exam. Portfast is a cisco network function which can be configured to resolve this problem. You also can configure bpdu protection for stp or mstp topologies at the edit protocols mstp stp hierarchy level.
When you configure bpdu guard globally, it is effective only on operational spanning tree edge ports. Bridge protocol data units bpdus are frames that contain information about the spanning tree protocol stp. Catalyst 4500 series switch cisco ios software configuration. Catalyst 3750x and 3560x software configuration guide, release 15. We will focus on spanning tree protocol stp configuration and verification commands in this tutorial, as implemented on cisco switches. As soon as two or more switches connect,spanning tree begins an election processto designate the root bridge. A port configured as access does not expect to see a bpdu from your log, thats what this means. Consolidated platform configuration guide, cisco ios. Cisco catalyst 2360 software configuration manual pdf download.
In our example we have a computer on the fa02 interface of sw2. Enable bpdu protection on interfaces that are configured as edge ports by using the bpdublockonedge command. What is bpdu filter and how to configure bpdu filter in. When a root receives the tcn bpdu, it transmits a configuration bpdu message on all the ports with topology change flag set to 1. To quickly configure bpdu protection on switch 2, copy the following commands and paste them into the switch terminal window. Im having an issue with spt after adding more vlans. Female narrator spanning tree protocolprevents switching loops.
Bpdu filter feature also can be enabled on an access port that should never receive a bpdu example. For, srx series devices with support for the enhanced layer 2 software els configuration style, you can configure bpdu protection globally on all spanning tree interfaces. Russell takes you through the installation, management, and troubleshooting of a mediumsized. Feb 05, 2014 remember for a cisco switch to see spanning tree on a non cisco switch you need to enable mstp on the cisco switch. Cisco spanning tree protocol guide stp examples and. In this scenario the bpdu frames are forwarded through the vds and reach physical switch port. A switch sends bpdus using a unique source mac address from its origin port to a multicast address with destination mac 01. Demonstrate your networking knowledge and expertise by earning a cisco ccna routing and switching certification.
If a switch port which is configured with spanning tree protocol stp portfast feature, it must be connected to an end device. Software configuration guide, cisco ios release 15. This propagates down the tree to the end of the path. Stp portfast bpdu guard is not available for the catalyst 8500 series, 2948gl3, or 4908gl3 switches.
In this sample chapter from scaling networks v6 companion guide, explore potential redundancy problems, symptoms, and protocols to manage them. When this happens, the switch shuts down the entire port on which the violation occurred. Bpdu guard feature must be enabled on a port that should never receive a bpdu from its connected device. Is bpdu filter enable best practice for access ports with po many thanks for everyones replies. Spanningtree bpduguard is one of the features that helps you protect your spanningtree topology.
By default spanning tree will send and receive bpdus on all interfaces. A ccie engineer recently came and configured two nexus 7000 switches for us and applied the spanningtree bpduguard enable and spanningtree bpdufilter enable on every access port which i found strange. For now im trying to set it up so all of my vlans just take the same route with the same root bridge. Cisco me 3400e ethernet access switch software configuration. Non cisco switches wont have any idea what to do with that.
Why would the switch say it received a bpdu on a port that is just connected to a pc. Stp bpdu filtering is it possible without bpdufilter. Network redundancy is a key to maintaining network reliability. Configuring bpdu protection on spanning tree interfaces.
When you enable bpdu guard at the interface level on any port without also enabling the portfast edge feature, and the port receives a bpdu, it. Spanning tree bpdu guard shuts down portfastconfigured interfaces that receive bpdus, rather than. Receipt of outside bpdus in an rstp or mstp, however, can lead to network outages by triggering an stp misconfiguration. Catalyst 2960 and 2960s switches software configuration. Enable bpdu protection on interfaces that are configured as edge ports by using the bpdu blockonedge command. The physical switch in turn disables the port because of the bpdu guard configuration. If a switch port which is configured with spanning tree protocol stp portfast feature, it must be connected to an end device for exampe. This topic applies to junos os for srx series devices with support for the enhanced layer 2 software els configuration style. At the global level, you enable bpdu guard on port fastenabled stp ports by using the spanningtree portfast. A cisco wap can actually convert an access port into a trunk without changing the visible switch configuration. The root bridge then makes decisions onwhat ports to block and which onesto put in a forwarding mode. At the interface level, you enable bpdu guard on any port by using the spanning tree bpduguard enable interface configuration command w. Some customers have experienced denial of service attack situations when a compromised virtual machine starts generating bpdu frames.
This factor of time is not an issue for many people, but it can cause problems for. Apr 15, 2016 catalyst 3560 switch software configuration guide, release 12. Jan 28, 2015 cisco switch how to configuring bpdu guard 1. Configuring switchport spanning tree bpdu guard free ccna.
238 1024 1488 437 375 1457 1062 1150 530 1139 509 1480 290 198 703 581 592 1532 275 1218 564 308 1684 675 1422 719 491 1400 378 1158 114 709 1268 1479 1073 829 775 1402 42